FUJITSU CentricStor V3.1D User Manual

Page 536

Advertising
background image

536

U41117-J-Z125-7-76

Message lines

Explanation of console messages

SXVW073

VLPWATCH: ALERT: VW(#073) AutoVLP-Failover: VLPwatch on <isp_name> is running,
communication to <isp_name> is defective (internal LAN or Broker on <isp_name>
down)!

Meaning
VLPwatch on the SVLP is running, but communication to the SVLP via the Broker has been
interrupted. The Broker on the SVLP is not running or the internal LAN on the SVLP is in-
terrupted.

Response
Determine the Broker status and the internal LAN status on the SVLP. Rectify the LAN or
Broker problems.

SXVW074

VLPWATCH: ALERT: VW(#074) AutoVLP-Failover: Communication to <isp_name> is
functional again!

SXVW098

VLPWATCH: WARNING: VW(#098) AutoVLP-Failover: VLPwatch is configured, but not
activated!

Meaning
The function is configured and has not yet been activated or has been deactivated manually
via the interface or has been deactivated implicitly by vtcon stop.

Response
The function must be activated via the GXCC interface (switch ON AutoVLP failover).

SXVW099

VLPWATCH: WARNING: VW(#099) AutoVLP-Failover: VLPwatch is configured, but not
activated!

SXVW099

VLPWATCH: WARNING: VW(#099) AutoVLP-Failover: VLPwatch must be deconfigured and
configured again!

Meaning
The function is still configured, but the initialization no longer exists. This is a possible con-
sequence of manual interventions or of implicit deactivation via vtcon stop.

Response
The function must be deconfigured via the interface (GXCC) with distribution to the entire
CentricStor system. If you require the function to be activated again, it must be configured
and distributed again.