Sxcm... (chim), 3 sxcm... (chim) – FUJITSU CentricStor V3.1D User Manual

Page 449

Advertising
background image

U41117-J-Z125-7-76

449

Explanation of console messages

Message lines

SXCH009

ESCON-adaptor <board> (ser_no <serial-nr) Compare Error in Channel <chn>

ALERT

Meaning
A test of the internal data paths on the ESCON board (PCEAS/PCEAT) which runs during
the startup phase and idle times returned an error.

Response
Replace the ESCON board.

SXCH010

ESCON-adaptor <board> CRC READ Error in Channel <chn>

ALERT

Meaning
During a read access the data was corrupted when it was transferred from the SINIX me-
mory to the ESCON channel.

Response
Replace the ESCON board.

SXCH011

ESCON-adaptor <board> CRC WRITE Error in Channel <chn>

ALERT

Meaning
During a write access the data was corrupted when it was transferred from the ESCON
channel to the SINIX memory.

Response
Replace the ESCON board.

9.2.3

SXCM... (CHIM)

SXCM001

chim1 (sadm9): SCSI-Bus reset

None

This message is part of a message complex (see the

section “Bus Reset for SCSI

Controller” on page 542

).

Advertising