FUJITSU CentricStor V3.1D User Manual

Page 282

Advertising
background image

282

U41117-J-Z125-7-76

History data

Global Status

Meaning of the columns:

pos

Line number

PV

Number of the physical volume

TL

Tape Library: Name of the archive

PVG Name of the physical volume group, usually starts at “CLNP”.
state status

The following values are possible for cleaning cartridges:
o___ (“scratch”) when the volume has just been added.
_r__ Read volume, has no more space for additional data. This is the normal

state of a cleaning cartridge.

f___ (“faulty”) when all the cleaning cycles have been used up.

max. count

Initial number of cleaning cycles

used_count

Number of cleaning cycles used

The PLM uses the cleaning cartridges as far as possible in such a way that one

cartridge is used up fully before the next one is started. However, if a number of
cleaning requests are to be carried out at the same time, the cartridges that are
available will also be used simultaneously.

When a specific physical volume is queried (volume number specified in the query box) a
detailed overview is output:

The data for the selected PV is output in the title bar (see

page 279

).

This is followed by a list of the (valid) logical volumes stored on the PV.

i