SXRD104

WARNING: raid 0:1:0 - Disk: Write-Only, 17300 MB

Meaning
A rebuild is active for the physical disk of controller 0, channel 1, target ID 0.

9.2.15.2

FibreCAT S80 messages

SXRD00<n>

s80d: RAID: <weight>: <raid-id> Raid<raid#> enclosure <shelf#> <component>
<status>

Meaning
If there is a status change in a S80 component, a message will be output on the console.

The terms used here have the following meanings:

n

1 - 8

weight

Error severity:

NOTICE

information

n=8,9

WARNING

soft error

n=6,7

ERROR

error

n=4,5

ALERT

critical error

n=2,3

raid-id

FibreCAT identification (target# of the 2 RAID controllers)

raid#

Number of the RAID system (1 – 8)

shelf#

Number of the shelf (1 – 7)

component

Internal component of the shelf

Disk drive (1 – 14)
Power supply (1 – 2)
Cooling fan (1 – 4)
Enclosure services module (1 – 2)
Loop monitor
Voltage sensor (1 – 6)
Current sensor (1 – 6)
Temperature sensor (1 – 4)

status

Status of the component

OK

Error corrected

Warning

Non-critical error (sensor only)

Critical

Critical error

Not Installed

Component removed or faulty

Not Available

Component not in operation

Unknown

Status not available (sensor only)