Fibrecat cx500 and cx3-20 messages – FUJITSU CentricStor V3.1D User Manual

Page 490

Advertising
background image

490

U41117-J-Z125-7-76

Message lines

Explanation of console messages

9.2.15.4

FibreCAT CX500 and CX3-20 messages

SXRD501

RAID: NOTICE <raid-id> Hard SCSI Error recovered (<#501>) c<ctrl>t<tgt>l<lun>

Where:
<raid-id>

ID of the FibreCAT (target # of the two RAID controllers)

c<ctrl>t<tgt>l<lun>

Path via which the message was transferred

(ctrl = controller#, tgt = target#, lun = logical device)

Meaning
Access via the specified path is possible again (positive message, cf. SXRD901).

SXRD901

RAID: ALERT <raid-id> Hard SCSI Error (<#901>) c<ctrl>t<tgt>l<lun>

Where:
<raid-id>

ID of the FibreCAT (target # of the two RAID controllers)

c<ctrl>t<tgt>l<lun>

Path via which the message was transferred

(ctrl = controller#, tgt = target#, lun = logical device)

Meaning
An error occurred while accessing the specified path. This can be the result of a defective
controller in theFibreCAT, an error in the FC switch or a defective cable.

Response
Notify maintenance staff.

Advertising