Sxvw... (vlpwatch), 28 sxvw... (vlpwatch) – FUJITSU CentricStor V3.1D User Manual

Page 523

Advertising
background image

U41117-J-Z125-7-76

523

Explanation of console messages

Message lines

9.2.28

SXVW... (VLPWATCH)

VLP failover messages

SXVW001

VLPWATCH: ALERT: AutoVLP-Failover: switch SVLP_to_VLP successfully completed!

Meaning
The switchover from the SVLP to the VLP has been successfully completed.

SXVW002

VLPWATCH: ALERT: AutoVLP-Failover: SVLP is not alive!

Meaning
The AutoVLP function is active on the VLP. The VLP has detected that there is no sign of
life from the required SVLP. The function is activated on the VLP, but without an active SVLP
no switchover is possible in the event of a failover. As long as the SVLP is missing, the
AutoVLP failover function is ineffective.

Response
You must investigate why the SVLP is not available. The SVLP and the AutoVLP failover
function must be activated.

SXVW003

VLPWATCH: NOTICE: VW(#003) AutoVLP-Failover: terminated, VLPwatch is already
started!

Meaning
The VLPwatch daemon for the AutoVLP failover function is already activated. The daemon
may only be activated once.

SXVW004

VLPWATCH: ERROR: VW(#004) AutoVLP-Failover: missing Licence of AutoVLP
(<lizenz>)!

Meaning
The license is not available for the AutoVLP failover function. This is required as of
CentricStor V3.0.

Response
Read in the license.

SXVW005

VLPWATCH: NOTICE: VW(#005) AutoVLP-Failover: VLPwatch is already active,
process terminated!

Meaning
The AutoVLP failover function has already been started on this ISP.

SXVW006

VLPWATCH: NOTICE: VW(#006) AutoVLP-Failover: VLPwatch started!

Meaning
The AutoVLP failover function has been started. This message is only for logging purposes.