496

U41117-J-Z125-7-76

Message lines

Explanation of console messages

SXSD017

shd<k>t<ctl>: cmd "Read" @ blk <n> key "Medium Error" (0x03) asc ....

ALERT

Meaning
Irrecoverable read errors occur sporadically on the FibreCAT RAID disk array despite
mirroring.

Response
Notify maintenance staff.

SXSD018

shd<k>t<ctl>: Target vanished

See the

section “Failover at the RAID system” on page 541

9.2.20

SXSE... (EXABYTE Tapes)

SXSE005

WARNING: exa: out of spt, deconfiguring exa

Meaning
The driver could not allocate any virtual adresses for IO mapping. No tape devices will be
usable for this ISP. Reason: the kernel has been modified. This error does not occur if the
standard kernel is used without any further tuning or modification.

Response
Notify maintenance staff.

SXSE006

mbk<n>t<t>: cmd 1B failed; status <...>

ALERT

This message is part of a message complex (see the

section “Timeout on the MTC drives”

on page 539

).

Advertising