Sxse... (exabyte tapes), 20 sxse... (exabyte tapes) – FUJITSU CentricStor V3.1D User Manual
Page 496

496
U41117-J-Z125-7-76
Message lines
Explanation of console messages
SXSD017
shd<k>t<ctl>: cmd "Read" @ blk <n> key "Medium Error" (0x03) asc ....
ALERT
Meaning
Irrecoverable read errors occur sporadically on the FibreCAT RAID disk array despite
mirroring.
Response
Notify maintenance staff.
SXSD018
shd<k>t<ctl>: Target vanished
See the
section “Failover at the RAID system” on page 541
9.2.20
SXSE... (EXABYTE Tapes)
SXSE005
WARNING: exa: out of spt, deconfiguring exa
Meaning
The driver could not allocate any virtual adresses for IO mapping. No tape devices will be
usable for this ISP. Reason: the kernel has been modified. This error does not occur if the
standard kernel is used without any further tuning or modification.
Response
Notify maintenance staff.
SXSE006
mbk<n>t<t>: cmd 1B failed; status <...>
ALERT
This message is part of a message complex (see the
section “Timeout on the MTC drives”
).