Fibrecat cx500 and cx3-20 messages – FUJITSU CentricStor V3.1D User Manual

Page 489

Advertising
background image

U41117-J-Z125-7-76

489

Explanation of console messages

Message lines

Response
In the event of a message with the error weight ALERT: Notify maintenance staff.

Example

SXRD003 s80d: RAID: ALERT: #212215 Enclosure 3, Power Supply 2 Critical

Connection between status and error weighting:

OK

NOTICE

Warning

WARNING

Not Available

ERROR

Unknown

ERROR

Critical

ALERT

Not Installed

ALERT

Messages with the error weighting ALERT trigger a teleservice call. For the S80 this
applies to all faulty components with the status “Critical” or “Not Installed” (faulty hard
disks have the status “Not Installed”).

A hardware fault can result in several different messages.

SXRD009

s80d: RAID: NOTICE: Raid<raid#>: <ccnt> Controller OK

Meaning
When the monitoring daemon starts (for example on reboot), information is read from the
connected FibreCAT S80 and the number of RAID controllers found per S80 is displayed
on the console.

The terms used here have the following meanings:

raid#

Number of the RAID system (1 – 8)

ccnt#

Number of the Controller (1 or 2)

9.2.15.3

FibreCAT CX500 and CX3-20 messages

SXRD010

RAID: ALERT <raid-id> Raid<raid#>: not all HBAs of <isp-name> registered

Where:
<raid-id>

ID of the FibreCAT (target# of the two RAID controllers)

<raid#>

Sequence RAID# (1 - 8)

<isp-name>

Name of the ISP concerned

Meaning
One or both HBAs of the specified ISP are not registered in the FibreCAT named.

Response
Notify maintenance staff.

Advertising