Explanation of console messages

Message lines

Response
Rectify the LAN connection problems and reboot the ISP.

SXVW012

VLPWATCH: ALERT: VW(#012) AutoVLP-Failover: FC connection to RAID is DOWN;
shutdown!

Meaning
There is no connection to the 1st RAID system. A shutdown with Power OFF was performed
for the ISP.

Response
Rectify the RAID problems and reboot the ISP.

SXVW013

VLPWATCH: ALERT: VW(#013) AutoVLP-Failover: SVLP (<isp_name>) is alive;
VLPwatch on <isp_name> not running!

Meaning
The VLP has detected that the SVLP can be reached via the LAN, but the VLPwatch
daemon for the AutoVLP failover function is not running on the SVLP.

Response
The function must be stopped manually via the interface (as of V3.0) and then restarted.

SXVW014

VLPWATCH: ALERT: VW(#014) AutoVLP-Failover: VLP (<isp_name>) is alive; VLPwatch
on <isp_name> not running!

Meaning
The SVLP has detected that the VLP can be reached via the LAN, but the VLPwatch
daemon for the AutoVLP failover function is not running on the VLP.

Response
The function must be stopped manually via the interface (as of V3.0) and then restarted.

SXVW015

VLPWATCH: NOTICE: VW(#015) AutoVLP-Failover: Raid currently not available!")

Meaning
The RAID is not available in the boot phase. Access to RAID is not yet possible. This occurs,
for example, when the entire CS system starts up again after a power failure. Access is
constantly repeated (timeout=30 minutes!).

Response
Check whether RAID is activated. If the message keeps appearing on the console (>10
MAL), abort the boot and examine why RAID access is not possible.

SXVW016

VLPWATCH: ALERT: VW(#016) AutoVLP-Failover: switch SVLP to VLP failed!

Meaning
The switchover of the SVLP to a VLP was aborted. The requirements were not met!