Message complexes, Timeout on the raid disk array, Section “timeout on the raid disk array” on – FUJITSU CentricStor V3.1D User Manual

Page 538: 3 message complexes, 1 timeout on the raid disk array

Advertising
background image

538

U41117-J-Z125-7-76

Message complexes

Explanation of console messages

9.3 Message complexes

9.3.1

Timeout on the RAID disk array

SXSB007

fcpal0 (sadm12): timeout on target <t> lun <l> CDB ....F C0 00 01 80 00

ALERT

0007b790: fc_send_fcp: FCP_ABORT...
0007b790: response: error = 0x03, vendor = 0x16, expl = 0x00, reason = 0x00,
action 0x00
0007b790: freeing FC_E_ABORT_REQUESTED

SXSD013

shd<k>t<ctl>: TIMEOUT @ nnnnnnn
shd<k>t<ctl>: REZEROING
shd<k>t<ctl>: rezero status = 2

Meaning
The message complex indicates a “normal” timeout on the RAID disk array, recovery
normally repeats the command with success.

Response
If the error messages occur sporadically, save the error messages. Otherwise they do not
indicate any significant operating problems. Notify maintenance staff.

Advertising