FUJITSU CentricStor V3.1D User Manual

Page 534

Advertising
background image

534

U41117-J-Z125-7-76

Message lines

Explanation of console messages

SXVW064 VLPWATCH: NOTICE: VW(#064) AutoVLP-Failover: only one mirror-side is accessible

wait maximum %d minutes to see an update of the timestamp of SVLP

Meaning
In the boot phase it is detected that only one mirror side is available. The situation and the
time stamp of the SVLP are monitored. If the timeout of up to 5 minutes has elapsed, a re-
quired action is initiated and logged accordingly.

Response
Take note of the next error message after the timeout!

SXVW065 VLPWATCH: ALERT: VW(#065) AutoVLP-Failover: only one mirror-side is available

and timestamp of SVLP is not updated

SXVW065 VLPWATCH: ALERT: VW(#065) AutoVLP-Failover: connection to LAN and start of

CentricStor prevented!

Meaning
In the boot phase the VLP master detects that it can only access one mirror side. The time
stamp of the SVLP has not been updated for 5 minutes. It is therefore assumed that a split-
brain situation exists: The CentricStor side with the SVLP has failed or is no longer acces-
sible. The VLP master is placed in Disconnect mode.

Response
Check the other CentricStor side to see whether a VLP or SVLP is active. Check the LAN
and FC connections of the ISPs of the type VLP, rectify any connection problems and reboot
the ISP.

SXVW066

VLPWATCH: ALERT: VW(#066) AutoVLP-Failover: Failover defect: check /etc/vtls/
log/.sw-<date>.err! - terminated!

Meaning
The check on the prerequisites for the function produced a negative result. The VLPwatch
daemon has been terminated.

Response
The cause must be determined by analyzing the switch-logdatei file and corrected.

SXVW067

VLPWATCH: ALERT: VW(#067) AutoVLP-Failover: check of /usr/apc/conf/vtls.conf
failed

Meaning
The entry for the SVLP or the entry for the VLM host assignment in the vtls.conf file is
not correct.

Response
The SVLP definition and the VLM host assignment must be checked and corrected if re-
quired.

Advertising