Sxvd... (distributed tape volume driver), 24 sxvd... (distributed tape volume driver) – FUJITSU CentricStor V3.1D User Manual

Page 516

Advertising
background image

516

U41117-J-Z125-7-76

Message lines

Explanation of console messages

SXTF011

DTV_FSCK(dev=<maj,min>): <message> ...<message>

Meaning
Normal output of the implicit file system check carried out when mounting a DTV file
system.

9.2.24

SXVD... (Distributed Tape Volume Driver)

SXVD001

vdrv<n> (FAILOVER): switch ...

ERROR

See the

section “Failure of RAID systems” on page 540

and the

section “Failover at the

RAID system” on page 541

.

SXVD002

vdrv<n> (FAILOVER): Error exit 0130002A E54EC000

See the

section “Failure of RAID systems” on page 540

.

SXVD003

vdrv<n> (MULTIPATH): switch 0:<n-2>->1:<n-1>

SXVD003

vdrv<n> (MULTIPATH): switch 1:<n-1>->0:<n-2>

Meaning
The path between the PC and the FC switch was switched over to a redundant (fallback)
path. This was due to disruption of the connection between the PC and the FC switch
caused, for example, by a controller failure (in the PC), GBIC failure, cabling problems, or
incorrectly identified topology.

Response
Notify maintenance staff.

SXVD004

vdrv<n> (FAILOVER): int switching

See the

section “Failover at the RAID system” on page 541

Advertising