Sxvd... (distributed tape volume driver), 24 sxvd... (distributed tape volume driver) – FUJITSU CentricStor V3.1D User Manual
Page 516

516
U41117-J-Z125-7-76
Message lines
Explanation of console messages
SXTF011
DTV_FSCK(dev=<maj,min>): <message> ...<message>
Meaning
Normal output of the implicit file system check carried out when mounting a DTV file
system.
9.2.24
SXVD... (Distributed Tape Volume Driver)
SXVD001
vdrv<n> (FAILOVER): switch ...
ERROR
See the
section “Failure of RAID systems” on page 540
and the
.
SXVD002
vdrv<n> (FAILOVER): Error exit 0130002A E54EC000
See the
section “Failure of RAID systems” on page 540
SXVD003
vdrv<n> (MULTIPATH): switch 0:<n-2>->1:<n-1>
SXVD003
vdrv<n> (MULTIPATH): switch 1:<n-1>->0:<n-2>
Meaning
The path between the PC and the FC switch was switched over to a redundant (fallback)
path. This was due to disruption of the connection between the PC and the FC switch
caused, for example, by a controller failure (in the PC), GBIC failure, cabling problems, or
incorrectly identified topology.
Response
Notify maintenance staff.
SXVD004
vdrv<n> (FAILOVER): int switching
See the