Cleaning physical drives, 5 cleaning physical drives – FUJITSU CentricStor V3.1D User Manual

Page 81

Advertising
background image

U41117-J-Z125-7-76

81

Selected system administrator activities

Cleaning physical drives

PLM Refresh Interval

Number of days after which the physical volumes in this group are to be recopied. The
count starts with the day on which the physical volume switched from scratch status to
write

status. This value must be defined in accordance with the recommendations of the

tape manufacturer.
Default:

365

4.5 Cleaning physical drives

The cleaning of physical drives can be carried out by the robots, or by CentricStor

(see

section “Physical Volume Operations » Add Physical Volumes” on page 223

).

Generally speaking, physical drives are cleaned automatically by the robots which means
that it is only necessary to check the cleaning tapes regularly.

However, the following robots are the exception to this rule:

SCALAR 1000 with a direct SCSI connection (not via DAS/ACI or SDLC) with
MAGSTAR drives

Since SCALAR 1000 has no special interface to the MAGSTAR drives that allow it to
see a clean request from the MAGSTAR drives, the system administrator must regularly
check the operating panel of the MAGSTAR drives.

MAGSTAR drives indicate a clean request by issuing a *CLEAN message to their
operating panel. And then the system administrator must trigger the cleaning process
by hand from the SCALAR 1000 operating panel.

SCALAR 100

SCALAR 100 also does not have an automatic cleaning feature. The drives indicate a
clean request via a special clean symbol (stylized broom) on the drive field of the
SCALAR 100 operating panel.

In this case, the system administrator must also trigger the cleaning process by hand
from the SCALAR 100 operating panel.

If the robots you are using do not offer an automatic cleaning function, CentricStor can also
take on the cleaning of physical drives.

Cleaning by CentricStor is carried out if the cleaning PVG that is automatically

created for each tape library provides cleaning tapes (see

section “Physical Volume

Operations » Add Physical Volumes” on page 223

and

section “Physical Compo-

nents” on page 254

).

i