Sxsm... (server management), 21 sxsm... (server management) – FUJITSU CentricStor V3.1D User Manual

Page 497

Advertising
background image

U41117-J-Z125-7-76

497

Explanation of console messages

Message lines

9.2.21

SXSM... (Server Management)

The term “sma#” used in this description is a collective term for the process names “sma”,
“sma02”, “sma03”, “sma04”, “sma05” and “sma06” which are specified in the error
messages in accordance with the hardware type of the SINIX server.

With the fan messages, the fan IDs <Id> have the following meaning:

SysFanx

System fan number x (e.g. SysFan3)

Cpux Fan

CPU fan number x (e.g. Cpu0 Fan)

PSx Fan

Power supply fan number x (e.g. PS1 Fan)

All error messages are also recorded in the default log file via V3 logging.

SXSM001

sma#: Power supply <Id> is not present

ALERT

Meaning
Redundant power supply module <Id> has not been installed.

Response
Notify maintenance staff.

SXSM002

sma#: Power supply <Id> is present and failed

ALERT

Meaning
Redundant power supply module <Id> has failed.

Response
Notify maintenance staff.

SXSM004

sma#: Fan <Id> is not working

ALERT

Meaning
Fan <Id> has failed and must be replaced. If the fan is inoperable for more than 3 minutes,
the SINIX system is shut down and the server deactivated to prevent the server from
overheating.

Response
Notify maintenance staff.

SXSM006

sma#: *** SHUTDOWN *** (Shutdown because of defective Fan [<Id>])

ALERT

Meaning
The SINIX system is shut down because a fan is defective and the server deactivated to
prevent the server from overheating.