You restart again. This time the process ends with the green message “Update done”.

It now makes sense to terminate the update tool by means of the “Cancel” button. The
service that monitors all the applications of the GXCC/XTCC family is thus restarted
with the updated version the first time one of these applications is started.

Repairing a faulty GXCC/XTCC version

In case the GXCC or XTCC version is faulty and you can therefore no longer call the
associated “Update / Revert” function and an installation CD is not available, a repair tool
has been provided as an emergency measure.

The prerequisites for using it are that you can access a system on which an operational
GXCC or XTCC version exists and that the faulty version provides a degree of basic
functionality.

If the tool cannot be run because the functionality of the faulty software is not sufficient or
one of the activities described below cannot be performed successfully, the only option is
to reinstall the GUI software from CD.

Call under SINIX/UNIX

To execute this you must switch to the XTCC directory <xtcc_path>.

cd <xtcc_path>
./repair &

Call under WINDOWS

If the following start menu entry is available:

Start » Programs » Fujitsu Siemens Computers » V6 Control Center » Setup
» Try to repair inoperable GXCC or XTCC

Otherwise:

Start » Execute » Browse
Select the file: <xtcc_path>\osd\Windows\repair.bat
» Open » OK

To do this on the WINDOWS NT/2000/XP platforms you require an ID with

administrator rights.