U41117-J-Z125-7-76

ESCON/FICON host adapter

XTCC

Channel Nodes

List of host channels used to establish a logical path. Each line
corresponds to one ESCON channel. The list shows the node
ID of the ESCON port in the host. The hexadecimal number
separated by a blank represents the port number of the host
channel on the ESCON Director (= link address).
The colon is followed by “chi” (= Channel Image) with a list of the
virtual channels of the host connected via this physical path.

To display formatted output of ESCON parameters, use the
“Show Node ID Details” command (see

page 381

).

Example for a FICON host adapter

The following information is also displayed in the information box:

Adapter Status

Active or stopped.

Board Number

Number of the adapter board.

Board Type

Board type.

Bus Type

Bus type.

Bus Number

Bus number.

Device Number

Position of the FICON host adapter in the ICP bus system.

WW Node Number

World Wide Node ID (WWNN)

WW Port Number

World Wide Port ID (WWPN)

Node ID

Node ID of the host adapters

Channel Nodes

List of host channels used to establish a logical path. For further
information see the example for an ESCON host adapter.

Connecting lines to the hosts

The connecting lines from the host adapter that go over the top of the screen show the host
devices connected.

The circle at the top of the line contains the device mnemonic. If the name is underscored
and the line continuous, the connection is active; the device is reserved and a logical path
has been established.

A dashed line indicates that a path has been established but no reservation exists.

If no line is displayed, no path has been established.