Sxrp... (rplm: recovery physical library manager) – FUJITSU CentricStor V3.1D User Manual

Page 491

Advertising
background image

U41117-J-Z125-7-76

491

Explanation of console messages

Message lines

9.2.16

SXRP... (RPLM: Recovery Physical Library Manager)

SXRP003

RPLM(#3): ALERT: <PDS-name> on <hostname> not reachable

Meaning
It was not possible to send a message to the PDS <PDS-name> on the host <hostname>.

Response
Check whether the PDS and/or host are running and whether the TCP/IP connection is
okay. If the corresponding IDP is running but the connection is not working, check the cables
and the hubs. Notify maintenance staff if necessary.

SXRP004

RPLM(#4): NOTICE: <PDS-name> on <hostname> reachable again

Meaning
The PDS <PDS-name> can be reached again.

SXRP005

RPLM(#5): CRITICAL: Physical Library Server <name> not reachable

Meaning
It was not possible to send a message to the PLS.

Response
Check whether the PLS is functioning.

SXRP006

RPLM(#6): NOTICE: Physical Library Server <name> reachable again

Meaning
It was again possible to send a message to the PLS.

SXRP013

RPLM(#13): ERROR: <PDS-name> reports media error on PV <PV-name>

Meaning
A media error has been reported on the physical volume <PV-name>.

Response
The physical volume has been marked by the PLM as read-only. Any logical volumes still
located on this physical volume should be moved by means of a reorganization. Once this
has been done, replace the physical volume.

SXRP014

RPLM(#14): ERROR: <PDS-name> reports hardware error

Meaning
The PDS <PDS-name> has reported a hardware error.

Response
Notify maintenance staff.

Advertising