Message lines

Explanation of console messages

Depending on the Primergy type the server will be reactivated after the wait time specified
in the BIOS setup and the system started up. This mechanism is governed by the “ASR&R
Boot Delay” and “Boot Retry Counter” entries in the BIOS setup.

Response
Notify maintenance staff.

SXSM006

sma#: *** SHUTDOWN *** (Shutdown temperature = <value> degrees Celsius at sensor
<Id>)

ALERT
SXSM006

sma#: *** SHUTDOWN *** (Shutdown because of critical temperature)

ALERT

Meaning
The critical temperature of a sensor has reached the shutdown threshold value. The SINIX
system is shut down and the server deactivated.

Depending on the Primergy type the server will be reactivated after the wait time specified
in the BIOS setup and the system started up. This mechanism is governed by the “ASR&R
Boot Delay” and “Boot Retry Counter” entries in the BIOS setup.

A defective temperature sensor

1

can also trigger this message.

Response
Notify maintenance staff.

SXSM009

sma#: Critical temperature = <value> degrees Celsius at sensor <Id>

ALERT

Meaning
The temperature of sensor <Id> is in the critical range. If a further temperature increase
exceeds a predefined limit value, a controlled shutdown will be initiated by the monitoring
software and the server deactivated.

A defective temperature sensor

1

can also trigger this message.

Response
Notify maintenance staff.

1

On the Primergy F250 the temperature sensors have the following meanings:
Sensor 0: CPU 0 temperature
Sensor 1: Inside temperature
Sensor 2: CPU 1 temperature
Sensor 3: Auxiliary = ambient temperature