Switching CentricStor off

Switching CentricStor on/off

Using GXCC or XTCC check that all the necessary CentricStor processes are running
(all processor boxes must be green).

5. BS2000/OSD:

Case 1: Host connection via ROBAR

Ê

Start ROBAR-SV (with the menu program robar or robar_start; see
ROBAR manual [

3

]).

Case 2: Host connection via CSC

Ê

Start CSC (see CSC manual [

4

]).

3.2 Switching CentricStor off

CentricStor can be switched off only in Service mode! As this mode is explained in

the CentricStor Service Manual, only a brief description is provided below.

The following sequence must be followed when switching off the individual CentricStor
components:

1. BS2000/OSD, z/OS and OS/390:

DETACH or VARY OFFLINE all logical drives on the host.

2. CentricStor is switched off via the GXCC user interface:

Ê

Activate the “Shutdown” function (see the Service Manual).

All CentricStor processors (VLP, IDPs, ICPs) and - if the “power off” option is
activated - the connected RAID system are then shut down gracefully and switched
off.

Ê

Wait for 5 minutes.

3. Switch off the hubs/switches (see corresponding operating instructions):

LAN hubs

fibre channel switches