FUJITSU CentricStor V3.1D User Manual

Page 219

Advertising
background image

U41117-J-Z125-7-76

219

GXCC

Function bar

Meaning of the information:

pos

Line number

PV

Number of the physical volume

TL

Name of the archive

PVG Name of the physical volume group, usually starts at “CLNP”.
state status

The following values are possible for cleaning cartridges:
o___ (“scratch”) when the volume has only just been added,
_r__ Read volume, has no more space for additional data. This is the normal

state of a cleaning cartridge.

f___ (“faulty”) when all the cleaning cycles have been used up.

max. count

Initial number of cleaning cycles

used_count

Number of cleaning cycles used

The PLM uses the cleaning cartridges in such a way that one cartridge is used up

fully before the next one is started. However, if a number of cleaning requests are
to be carried out at the same time, the cartridges that are available will be used
simultaneously.

When a specific physical volume is queried (volume number specified in the query box)
a detailed overview is output:

The data for the selected PV is output in the title bar.

i