6. Diagnosis and fault display

6−16

Festo P.BE−GDCP−SFC−LACI−PB−E N en 0812NH

16 bytes are reserved for diagnosis in the SFC−LACI:

Byte

Diagnostic address

Description

0

Station status 1

Gives an overview of the communication status and the
general status of the SFC LACI

1

Station status 2

general status of the SFC−LACI
(see Tab. 6/12 ff )

2

Station status 3

(

/

)

3

Master PROFIBUS address

PROFIBUS address of the DP master via which the
SFC−LACI was parameterised and which has both read and
write access.

4

DP slave ID number

Describes the DP slave type
(for SFC LACI

0974h)

5

(for SFC−LACI = 0974h)

6

Header (for the device−related
diagnosis)

Specifies the length of the device−related diagnosis incl.
header (fixed = 10)

7

Status type

With the SFC−LACI always 0xA0
(for manufacturer−specific status")

8

Slot number

With the SFC−LACI always 0x00
(slot is ignored)

9

Specifier

With the SFC−LACI always 0x00
(no specification of the error)

10

Device−related diagnosis 1:
Firmware version number

SFC−LACI firmware version number:

1)

Byte 11: Main version

11

Firmware version number

Byte 11: Main version
Byte 10: Subsidiary version

12

Device−related diagnosis 2:
Hardware version number

SFC−LACI hardware version number:

1)

Byte 13: Main version

13

Hardware version number

Byte 13: Main version
Byte 12: Subsidiary version

14

Device−related diagnosis 3:
Fault number

For fault number, see Tab. 6/10

15

Fault number

1)

e.g.Ă0x02 0x01"

Z V1.02

Tab. 6/11:

DP diagnosis (Device−related diagnosis)