3. Installation
3−4
Festo P.BE−GDCP−SFC−LACI−PB−E N en 0812NH
1
Parameterising
interface (RS232)
2
Controller interface
3
Voltage supply
4
Earth terminal
5
Local digital I/Os
6
Motor connection
(e.g.ĂDNCE−...−LAS)
1
2
3
4
5
6
Fig. 3/1:
Connections to the SFC−LACI
Connection to the SFC−LACI−PB
Description
1
Parameterising
interface
M8 socket, 4−pin
RS232 interface for parameterising, commissioning
and diagnosis via FCT
} section 3.5
2
Controller
interface
Sub−D, 9−pin,
socket
Interface for connecting to a PLC controller
} section 3.6
3
Voltage supply
Sub−D plug, 7WT
Voltage connection with 2 high−current contacts and
5 low−current contacts (separate load and logic
voltage supply)
} section 3.2
4
Earth terminal
Stud bolt, M4
Connection for functional earth
} section 3.3
5
Local digital I/Os
M8 socket, 3−pin
Local digital inputs and outputs
} section 3.9
6
Motor terminal
Plug connector,
typeĂITT Cm3
Power supply for linear motor and sensor signals
} section 3.4
Tab. 3/1: