A. Technical appendix

A−4

Festo P.BE−GDCP−SFC−LACI−PB−E N en 0812NH

Electrical data

Load voltage supply
Ĉ Nominal voltage
Ĉ Nominal current (max. contin. motor current)
Ĉ Peak current

Power connection, pins A1, A2)
48 VDC (+5/−10 %) (Load power down:

Ţ 36 V)

10 A
20 A

Logic voltage supply
Ĉ Nominal voltage
Ĉ Peak current

Power connection, pins 1, 2
24 VDC ±10 %
3.8 A (when using the local digital outputs,
see section 3.2)

Protection against electric shock
(protection against direct and indirect contact as
per IEC/DIN EN 60204−1)

By means of PELV power circuit
(Protected Extra−Low Voltage)

Parametrising interface specification

RS232, see sections 3.5 and B.4.3

PROFIBUS data

Protocol

PROFIBUS−DP (DPV0, DPV1)

Baud rates

9.6 kBd ... 12 MBd,
automatic baud rate recognition

Interface
Ĉ Plugs
Ĉ Version
Ĉ Type of transmission
Ĉ Integrated bus termination

Sub−D, 9−pin
RS485, voltage−free
Serial asynchronous, half duplex
None

Cable type

Depends on length of cable and field bus baud
rate, see controller manual