Festo Контроллеры двигателя SFC-LAC User Manual
Page 218

A. Technical appendix
A−4
Festo P.BE−GDCP−SFC−LACI−PB−E N en 0812NH
Electrical data
Load voltage supply
Ĉ Nominal voltage
Ĉ Nominal current (max. contin. motor current)
Ĉ Peak current
Power connection, pins A1, A2)
48 VDC (+5/−10 %) (Load power down:
Ţ 36 V)
10 A
20 A
Logic voltage supply
Ĉ Nominal voltage
Ĉ Peak current
Power connection, pins 1, 2
24 VDC ±10 %
3.8 A (when using the local digital outputs,
see section 3.2)
Protection against electric shock
(protection against direct and indirect contact as
per IEC/DIN EN 60204−1)
By means of PELV power circuit
(Protected Extra−Low Voltage)
Parametrising interface specification
RS232, see sections 3.5 and B.4.3
PROFIBUS data
Protocol
PROFIBUS−DP (DPV0, DPV1)
Baud rates
9.6 kBd ... 12 MBd,
automatic baud rate recognition
Interface
Ĉ Plugs
Ĉ Version
Ĉ Type of transmission
Ĉ Integrated bus termination
Sub−D, 9−pin
RS485, voltage−free
Serial asynchronous, half duplex
None
Cable type
Depends on length of cable and field bus baud
rate, see controller manual