Festo Контроллеры двигателя SFC-LAC User Manual

Page 269

Advertising
background image

B. Supplementary information

B−49

Festo P.BE−GDCP−SFC−LACI−PB−E N en 0812NH

Record pointer:
The active record for

positioning or teaching is selected via

PNU 400.

Record Number FHPP

PNU

400

1 ... 3

0 ... 2

uint8

r(w)

Description

FHPP record number

Record Number 400

1

0

rw

Record pointer for positioning and teaching.
It is also valid when the drive is not in Record select mode (e.g.Ăduring teaching).
For record selection this parameter is transferred in the cyclic I/O data.
Value range: 0 ... 34 (0x00 ... 0x22)
Values:
0 (0x00):

Homing (positioning record 0)

1 (0x01):

Positioning record 1

2 (0x02):

Positioning record 2

...:

Positioning record ...

31 (0x1F):

Positioning record 31

32 (0x20):

Inching mode

33 (0x21):

Direct mode

34 (0x22):

FCT positioning record

Active Record 400

2

1

r

The number of the active record. relevant for record chaining.

Record Status Byte 400

3

2

r

Contains FHPP status byte 4 with information on record chaining
(see section 5.6.3)

CI

2033h

01h ... 03h

uint8

r(w)

Note: The object 2032h is provided for access via CI.

Advertising