Festo Контроллеры двигателя SFC-LAC User Manual
Page 263

B. Supplementary information
B−43
Festo P.BE−GDCP−SFC−LACI−PB−E N en 0812NH
FHPP Control Data
PNU
321
1 ... 2
Record
uint32
r
Description
FHPP output data (8 bytes of status date), 4 bytes each, consistent
1
FHPP control bytes 1 ... 4 (CCON, CPOS, ...)
2
FHPP control bytes 5 ... 8 (setpoint position)
CI
20A1h
01h ... 02h
uint32
r
Control Word
PNU
330
ć
uint16
rw
Description
Control word: Modify the current controller status or trigger an activity.
As status modifications require a certain amount of time, all status modificaĆ
tions triggered via the control word must be read back via the status word
(6041h). Further commands cannot be written via the control word until the
requested status can be read in the status word.
Typical values: see Tab. B/9
Bit assignment: see Tab. B/10
CI
6040h
00h
uint16
rw
Value
Function
0x000F
ENABLE OPERATION, Controller enable
0x000D
VOLTAGE DISABLE, end stage off
0x001F
Start ABSOLUTE movement
0x005F
Start RELATIVE movement
0x010F
Stop movement
0x008F
Reset error + ENABLE OPERATION
0x004F
Set target position as RELATIVE
Tab. B/9:
Typical values control word