Parameter reference travel

Offset Axis Zero Point

PNU

1010

ć

ć

int32

rw

Description

Offset of the axis zero point AZ to the reference point REF in [Increments]
(= distance from reference point). Factory settings: see section 5.2.4.
The drive is no longer referenced after the axis zero point has been modified.

CI

607Ch

00h

int32

rw

Homing Method

PNU

1011

ć

ć

uint8

rw

Description

Reference travel (homing) method.
Values

Function

1 (0x01):

Search for limit switch in negative direction with index search

2 (0x02):

Search for limit switch in positive direction with index search

7 (0x07):

Search for reference switch in positive direction with index search

11 (0x0B):

Search for reference switch in negative direction with index search

−18 (0xEE): Search for stop in positive direction
−17 (0xEF): Search for stop in negative direction
The drive is no longer referenced after the reference travel (homing) method
has been modified.

CI

6098h

00h

uint8

rw

Homing Velocities

PNU

1012

1 ... 2

0 ... 1

int32

rw

Description

Speeds during reference travel

Search REF

(search for REF)

1012

1

0

(search for REF)

Speed when searching for the reference point REF in [Inc/s]

Search AZ

(search for AZ)

1012

2

1

(search for AZ)

Speed of travel to the axis zero point AZ in [Inc/s]

CI

6099h

01h...02h

int32

rw

Advertising