B. Supplementary information
B−112
Festo P.BE−GDCP−SFC−LACI−PB−E N en 0812NH
Version FCT PlugIn Min.
CI
2067h
00h
Var
V−string
r
Description
Minimum FCT version required
Format = xx.yy" (xx = main version, yy = secondary version)
Version FCT PlugIn Opt.
CI
2068h
00h
Var
V−string
r
Description
Optimum FCT version
Format = xx.yy" (xx = main version, yy = secondary version)
Scaling
CI
20D0h
01h, 02h
Array
uint8
r
Description
Units of measurement and decimal places on the control panel.
See CI object 20FFh/PNU 126
Measuring Unit
(unit of
20D0h
01h
uint8
r
(unit of
measurement) Definition of unit of measurement.
The setting for the system of measurement only affects the display.
All parameters are converted to the given unit of measurement only during
writing or reading.
Note:
The SFC−LACI operates internally with metric units; the CI interface with
increments.
Value: Fixed = 1: millimetres, e.g. mm, mm/s, mm/s
2
Scaling Size
(no of places after
20D0h
02h
uint8
r
(no. of places after
dec. point) Number of places after the decimal point.
Fixed = 2