B.3
Reference FHPP parameters (PNU)
B.3.1
Parameter groups
Group
PNU
Description
Device data
100 ... 199
Device identification and device−specific settings, version
numbers, identifier words, etc.
Diagnostic memory
200 ... 299
Memory for diagnostic events: Fault numbers, fault time,
incoming/outgoing event
Process data
300 ... 399
Current setpoint and actual values, local I/Os, status data etc
Position record
table (= Record list)
400 ... 499
A record contains all the setpoint value parameters required
for a positioning procedure
Project data
500 ... 599
Basic project settings. Maximum speed and acceleration,
project zero point offset, etc.
} These parameters form the basis of the position set table
Factor group
600 ... 699
Reserved
Axis data
Electric drives 1
1000 ... 1099
All axis−specific parameters for electric drives. Gear factor,
feed constant, reference parameter, etc.
Axis data
Electric drives 2
1200 ...
Enhancements
Tab. B/8:
FHPP parameter groups