B. Supplementary information

B−93

Festo P.BE−GDCP−SFC−LACI−PB−E N en 0812NH

B.4.3

Access via a terminal program

For data transmission you will require a commercially−
available terminal program or the integrated CI terminal of
the SFC−LAC PlugIn in the Festo Configuration Tool.

1. Connect the SFC−LACI to your PC (see section 3.5).

2. Configure your PC’s COM interface:

Settings of the COM interface

Transmission speed (baud rate)

38400 Baud

Data format

Asynchronous character frame:
Ĉ 1 start bit
Ĉ 8 data bits
Ĉ no parity bit
Ĉ 1 stop bit

Tab. B/13:

Settings of the COM interface

3. You can use the following command to initialise data

transmission and determine the SFC−LACI’s response
readiness:

Command

Reply

1 <CR>

11 <CR>