B. Supplementary information

B−75

Festo P.BE−GDCP−SFC−LACI−PB−E N en 0812NH

Drive Data

PNU

1026

Various

Various

uint32

r(w)

Description

General data of the SFC−LACI

Output Stage

Temp

1026

1

0

r

Temp.

Temperature of the SFC−LACI; range: −20 ... +120 °C

Output Stage

Max Temp

1026

2

1

r

Max. Temp.

Highest temperature measured to date for the SFC−LACI, in °C.
Stored in EEPROM

Max. Current

1026

4

3

rw

Current limiting. Identical to PNU 1034/6073h and 6510/41h

Device Control 1026

6

5

rw

Identical to PNU 125/207Dh
Bit 0 = 0: Control interface OFF, control via HMI or FCT ON
Bit 0 = 1: Control interface ON
To enable FCT control after the control interface has been switched off,
set ENABLE OPERATION in the control word as well (objectĂ6040h).

Controller Serial

Number

1026

7

6

r

Number

Serial number of the SFC−LACI

CI

6510h

01h, 02h, 04h, 06h, 07h

uint32

r(w)

Further subindices of 6510h: see section B.5.1.

I

2

t Value

PNU

1027

ć

ć

uint32

r

Description

Actual I

2

t value. See PNU 1025/3

CI

6410h

04h

uint32

r