Festo Контроллеры двигателя SFC-LAC User Manual
Page 258

B. Supplementary information
B−38
Festo P.BE−GDCP−SFC−LACI−PB−E N en 0812NH
PROFIBUS Diagnosis
PNU
206
1 ... 6
0 ... 5
uint8
r
Description
Reading the PROFIBUS diagnostic data
Connection State 206
1
0
0 (0x00):
Waiting for parameterising
16 (0x10): Waiting for configuration
32 (0x20): Data exchange
Baud Rate 206
2
1
0 (0x00): 12 MBaud
6 (0x06): 93.75 kBaud
1 (0x01): 6 MBaud
7 (0x07): 45.45 kBaud
2 (0x02): 3 MBaud
8 (0x08): 19.2 kBaud
3 (0x03): 1.5 MBaud
9 (0x09): 9.6 kBaud
4 (0x04): 500 kBaud
15, 255 (0x0F, 0xFF): no baud rate (default)
5 (0x05): 187.5 kBaud
Baud rate search active
Master Address 206
3
2
Value range: 0 ... 125 (0x00 ... 0x7D). Default: 255 (0xFF)
Slave Address 206
4
3
Value range: 0 ... 125 (0x00 ... 0x7D). Default: 255 (0xFF)
Configuration 206
5
4
0 (0x00): Invalid configuration (default)
1 (0x01): Festo FHPP standard (8 bytes I/O)
2 (0x02): Festo FHPP standard + FPC (2 x 8 bytes I/O)
Settings
(connection
206
6
5
(connection
settings) 0 (0x00): Device−related diagnosis ON (default)
1 (0x01): Device−related diagnosis OFF
CI
2FF4h
01h ... 06h
uint8
r