B. Supplementary information

B−38

Festo P.BE−GDCP−SFC−LACI−PB−E N en 0812NH

PROFIBUS Diagnosis

PNU

206

1 ... 6

0 ... 5

uint8

r

Description

Reading the PROFIBUS diagnostic data

Connection State 206

1

0

0 (0x00):

Waiting for parameterising

16 (0x10): Waiting for configuration
32 (0x20): Data exchange

Baud Rate 206

2

1

0 (0x00): 12 MBaud

6 (0x06): 93.75 kBaud

1 (0x01): 6 MBaud

7 (0x07): 45.45 kBaud

2 (0x02): 3 MBaud

8 (0x08): 19.2 kBaud

3 (0x03): 1.5 MBaud

9 (0x09): 9.6 kBaud

4 (0x04): 500 kBaud

15, 255 (0x0F, 0xFF): no baud rate (default)

5 (0x05): 187.5 kBaud

Baud rate search active

Master Address 206

3

2

Value range: 0 ... 125 (0x00 ... 0x7D). Default: 255 (0xFF)

Slave Address 206

4

3

Value range: 0 ... 125 (0x00 ... 0x7D). Default: 255 (0xFF)

Configuration 206

5

4

0 (0x00): Invalid configuration (default)
1 (0x01): Festo FHPP standard (8 bytes I/O)
2 (0x02): Festo FHPP standard + FPC (2 x 8 bytes I/O)

Settings

(connection

206

6

5

(connection

settings) 0 (0x00): Device−related diagnosis ON (default)

1 (0x01): Device−related diagnosis OFF

CI

2FF4h

01h ... 06h

uint8

r