Motor Type

PNU

1030

ć

ć

uint16

r

Description

Classification of the motor. Fixed: 0x0000

CI

6402h

00h

uint16

r

Max. Current

PNU

1034

ć

ć

uint16

rw

Description

Maximum motor current in per mill of rated current (PNU 1035).
Note:
The current limitation also limits the max. possible speed (orĂforce).
Higher setpoint speeds may not therefore be reached, or the drive stops.
During homing: At greatly reduced values combined with high travelling
resistance, there is a danger that the drive will come to a standstill and the
SFC−LACI will wrongly recognize a stop.

CI

6073h

00h

uint16

rw

Motor Rated Current

PNU

1035

ć

ć

uint32

rw

Description

Nominal current of the motor in [mA]. The value is fixed.

CI

6075h

00h

uint32

rw

Motor Rated Torque/Force

PNU

1036

ć

ć

uint32

rw

Description

Nominal force of the linear motor in [mN]. The value is fixed.

CI

6076h

00h

uint32

rw

Advertising