Page 225

B. Supplementary information
B−5
Festo P.BE−GDCP−SFC−LACI−PB−E N en 0812NH
B.1.1
Create readiness to operate
With the transitions only those internal conditions are named
which are new. There must therefore not be any faults for T2.
T
Internal conditions
Actions of the user
T1
SFC−LACI was switched on
No error is detected
T2
Supply voltage applied
Drive control for field bus master
ENABLE = 1 (drive enabled)
CCON = xxx0.xxx
1
T3
STOP = 1
CCON = xxx0.xx
11
T4
STOP = 0
CCON = xxx0.xx
01
T5
ENABLE = 0
CCON = xxx0.xxx
0
T6
ENABLE = 0
CCON = xxx0.xxx
0
T7*
Fault detected
T8
Reaction to fault completed, drive stopped
T9
A fault is no longer present
Was a serious error
RESET = 0
→1 (acknowledge fault)
CCON = xxx0.
Pxxx
T10
A fault is no longer present
Was a slight error
RESET = 0
→1 (acknowledge fault)
CCON = xxx0.
Pxx1
T11
Fault is still present
RESET = 0
→1 (acknowledge fault)
CCON = xxx0.
Pxx1
Key: P = positive edge
N = negative edge
x = any