B.3.9 axis parameters for electric drives 1, B.3.9, Axis parameters for electric drives 1 – Festo Контроллеры двигателя SFC-LAC User Manual
Page 287: B−67, Direct mode: fhpp continuous mode
Advertising

B. Supplementary information
B−67
Festo P.BE−GDCP−SFC−LACI−PB−E N en 0812NH
Direct mode: FHPP Continuous Mode
Interpolation Time
PNU
570
ć
ć
uint16
rw
Description
Time gap between two position specifications in FHPP Continuous Mode" in
[
1
/
10
ms]. Value range: 0 ... 65535. See section 5.7.7
CI
20B6h
00h
uint16
rw
B.3.9
Axis parameters for electric drives 1
Mechanical parameters
Polarity
PNU
1000
ć
ć
uint8
r
Description
Reversal of direction. Fixed = 1 (not adjustable)
CI
607Eh
00h
uint8
r
Encoder Resolution
PNU
1001
1 ... 2
0 ... 1
uint32
r
Description
Measurement system resolution. Reflects 6410/12h
Encoder Increments 1001
1
0
Number of increments between two index pulses. Fixed = 2048
Motor Revolutions 1001
2
1
Fixed = 1
CI
608Fh
01h ... 02h
uint32
r