Festo Контроллеры двигателя SFC-LAC User Manual
Page 264

B. Supplementary information
B−44
Festo P.BE−GDCP−SFC−LACI−PB−E N en 0812NH
Bit
Value
Description
0 ... 8
Bits 0 ... 8 are only used together
Ĉ for access via the CI interface: see Tab. B/9
9
0x0200
Reserved (= 0)
10
0x0400
11
0x0800
Jog mode positive (like FHPP CPOS.B3)
12
0x1000
Jog mode negative (like FHPP CPOS.B4)
13
0x2000
Teach (like FHPP CPOS.B5)
14
0x4000
In direct mode:
0 = normal path generator
1 = energy optimized
Note: Only available for control via the field bus, not via CI.
15
0x8000
In direct mode:
0 = configured values for acceleration and deceleration
1 = symmetrical ramp (deceleration = acceleration)
Note: Only available for control via the field bus, not via CI.
Tab. B/10:
Control word bit assignment
Status Word
PNU
331
ć
uint16
r
Description
Status word: Reading the controller state.
Bit assignment: see Tab. B/11
CI
6041h
00h
uint16
r