B.3.5

Diagnosis

Description of the method of operation of the diagnostic
memory: see section 6.4.

Diagnostic Event

PNU

200

1 ... 16

d

0 ... 15

d

uint8

r

Description

Type of fault or diagnostic information saved in the diagnostic memory.
Displays whether an incoming or outgoing fault is saved.

Value

Type of diagnostic event

0 (0x00)

No fault (or diagnostic message deleted)

1 (0x01)

Incoming fault

2 (0x02)

Outgoing fault

3 (0x03)

(reserved)

4 (0x04)

Overrun time stamp

Event 1 200

1

0

Active diagnostic event

Event 2 200

2

1

Previous diagnostic event

Event ... 200

...

...

...

Event 16 200

16

15

Oldest saved diagnostic event