alarms

alarms

Use the alarms command to display the active alarms. Each alarm is related to a particular
address and has a severity category (major, minor, critical, alert). The report can be filtered by
port address and/or severity.

Syntax:

alarms [slot|slot:port|slot:port:channel] [category]

[severity]

Example:

alarms

Time Date Severity Description

07:35:45 01/04/2002 Major Test Major Alarm

07:35:21 01/04/2002 Minor Test Minor Alarm

07:34:57 01/04/2002 Critical Test Critical Alarm

00:00:20 01/01/2002 Major 5:1-RTR Ethernet Link Down

00:00:05 01/01/2002 Major A:2-DS1 Loss Of Signal

Total=10

[slot|slot:port|slot:port:channel]

[category]

[severity]

slot

A for the controller card, or 1 - 6 for service cards.

port

Port number.

channel

Channel number

bri

All BRI facility alarms

ds1

All DS1 facility alarms

env

Environmental Alarms

equipment

Equipment alarms not related to a DS1 interface

fxo

All FX0 facility alarms

fxs

All FXS facility alarms

rtr

All Router facility alarms

v35

All V.35 facility alarms

alert

Alert alarms (threshold crossing)

critical

Critical alarms

info

Information alarms

major

Major alarms (service effecting)

minor

Minor alarms (non-service affecting)