Set ethernet ip address, Set (fxo), Set ethernet ip address -79 – Black Box COMPACT T1 MT850A User Manual

Page 163: Set (fxo) -79

Advertising
background image

Compact T1 - Release 6.1

5-79

CLI Commands

set

set ethernet ip address

Use the set ethernet ip address command to set the Ethernet address for the Compact T1.

Syntax:

set ethernet ip address {ip-addr} [mask]

Example:

set ethernet ip address 172.26.100.25 255.255.255.0

Sets the Adit IP address to 172.26.100.25, and a subnet mask of 255.255.255.0.

{ip-addr}

Set the IP address for the Compact T1, using the form xxx.xxx.xxx.xxx, where xxx is a
number from 0 to 255.

[mask]

Set the subnet mask, using the form xxx.xxx.xxx.xxx, where xxx is a number from 0 to 255.
This is an optional setting.

set (fxo)

Use the set (fxo) command to setup one/all of the voice channels of an FXO card. The command
specifies the list of voice channels within that card, and the setting to apply.

Syntax:

set {fxo-addr} {setting}

Example:

set 2:1 signal ls

Set the FXO on slot 2, port 1 to signaling type loop start.

{fxo-addr}

List of voice channels to apply setting to, in the form {slot:port}.

{setting}

slot

Slot number 1 - 6, location of the FXO card

port

Port number or range

rxgain

The receive level range is -9 to +7 (db). Available values are -9, -7, -6, -5,
-4, -3, -2, 0, 2, 3, 4, 5, 6, and 7

signal

Set the DS0 signaling type

dpt

Set the DS0 to Dial Pulse Terminate

gs

Set the DS0 to Ground Start signaling

ls

Set the DS0 to Loop Start signaling

lscpd

Set the DS0 to Loop Start Calling Party Disconnect

txgain

The transmit level range is -9 to +7 (db). Available values are -9, -7, -6,
-5, -4, -3, -2, 0, 2, 3, 4, 5, 6, and 7

Advertising