Black Box COMPACT T1 MT850A User Manual

Page 161

Advertising
background image

Compact T1 - Release 6.1

5-77

CLI Commands

set

framing

Set the DS1 framing type to one of the following:

d4

To D4 Superframe (SF) framing

esf

To Extended Superframe (ESF) framing

tr8afdl

TR-08 A shelf framing with FDL

tr8anofdl

TR-08 A shelf framing with no FDL

tr8b

TR-08 B shelf framing

id

Set the DS1 circuit identification string. This is the same as dsx1Circuit
Identifier from DS1 MIB transmission vendor’s identification. String
text must be enclosed in quotes

.

Example: set {ds1-addr} id {"string"}

lbo

Set the Line Build Out (LBO) to one of the following:

1

DSX-1 equalization for 0-133 feet (equivalent to CSU
attenuation for LBO of 0dB)

2

DSX-1 equalization for 133-266 feet

3

DSX-1 equalization for 266-399 feet

4

DSX-1 equalization for 399-533 feet

5

DSX-1 equalization for 533-655 feet

6

CSU attenuation for LBO of -7.5dB

7

CSU attenuation for LBO of -15dB

8

CSU attenuation for LBO of -22.5dB

line

Turn a line loopback to the DS1 interface on or off. If the line command
is not used, the default for line loopback is loopdown.

loopdown

Disable the line loopback

loopup

Enable a DS1 line loopback toward the DS1 drop

linecode

Set the DS1 interface line coding to one of the following. If the linecode
command is not used, the default for linecode is B8ZS.

ami

Alternate Mark Inversion line coding

b8zs

Binary 8 Zero Substitution line coding.

loopdetect

Enable detection of CSU loop code (10000 for loopup; 100 for
loopdown)

Advertising