B-12

Compact T1 - Release 6.1

Diagnostices & Troubleshooting

Loopbacks Overview

DS1 Equipment Loop

Note: Quad T1 LED stays green during equipment loop. The DS1 Equipment
Loopback is available on the Quad T1 card and is not available on the Controller
card.

Enable Equipment Loopback

Where a Quad T1 card is in slot 5.

> set 5:1 equipment loopup

OK

View Status of Loopback

> show 5:1

SLOT 5:

Settings for DS1 1:

Circuit ID: DS1# 5:1

Up/Down: UP

Framing: ESF

Line Coding: B8ZS

Line Build Out: DSX-1 EQUALIZATION FOR 0-133 ft.

(CSU 0dB)

Loop Code Detection: ON

Loopback: EQUIPMENT

FDL Type: None

Performance Threshold Settings 15 min. 1 day

T1

Adit 600

Quad T1

Loops at local Quad

T1 port (location)

PBX

FXS

Telephone

DS1

Network

Compact T1