Fxs signaling performance, Fxs signaling performance -5 – Black Box COMPACT T1 MT850A User Manual

Page 399

Advertising
background image

Compact T1 - Release 6.1

8-5

FXS Voice Card

Technical Specifications

FXS Signaling Performance

l

DC Loop Range: 1000

standard, 1600

extended

l

Loop Feed: Nominal -48 VDC with 31mA current limit for long loops, -36 VDC
@ 27mA for short loops with automatic battery switching

l

Off-Hook Detection: Detects tip or ring currents > 6mA

l

Ring Ground: Detects ring ground currents > 8mA

l

Ringing Voltage: All-channel simultaneous ringing power, 85 V rms, 20 Hz

l

Maximum Ringers: 5 REN, FCC Class B ringers

l

Internal Ringing Cadence: Ringing cadence is 2 seconds on, 4 seconds off for
E&M wink start conversion modes

l

Control Technique: Solid-state with no mechanical relays

l

Overvoltage: UL 1950, FCC Part 68 lightning protection

l

Overcurrent: 600 V rms, 60 Amps

l

Supports CLASS features such as calling party ID, three-way calling, and
distinctive ringing

l

Calling Party Disconnect: Calling party (forward) disconnect provides 2 second
current interruption to disconnect answering devices and modems - requires
E&M signaling service on the T1

l

FXS Signaling: FXS loop start or FXS ground start with LS/GS selection per
channel

l

FXSDN Signaling: E&M immediate or wink start to either loop start or ground

start conversion with ringback tone for carrier services such as Megacom

®

,

Flexpath

®

, DSS

®

, VPN

®

, VNET

®

, etc. Wink delay for advanced ANI/DNIS 800

number services

l

Ringer Equivalency Number (REN): 0.0 by definition