Clear alarm – Black Box COMPACT T1 MT850A User Manual

Page 532

Advertising
background image

B-4

Compact T1 - Release 6.1

Diagnostices & Troubleshooting

Alarms

Display Alarms

Use the alarms command to display the active alarms. Each alarm is related to a
particular address and has a severity category (major, minor, critical, alert). The
report can be filtered by port address and/or severity.

Syntax:

alarms [slot|slot:port|slot:port:channel] [category]

[severity]

> alarms

Time Date Severity Description

07:35:45 01/04/2002 Major Test Major Alarm

07:35:21 01/04/2002 Minor Test Minor Alarm

07:34:57 01/04/2002 Critical Test Critical Alarm

07:30:39 01/04/2002 Major 1:1-OCUDP Out of Service

03:50:55 01/04/2002 Major 1:1-OCUDP Loss of Signal

00:00:20 01/01/2002 Major 4:1-CMG Ethernet Link Down

00:00:20 01/01/2002 Major 5:1-RTR Ethernet Link Down

00:00:05 01/01/2002 Major A:2-DS1 Loss Of Signal

00:00:05 01/01/2002 Major A:1-DS1 Loss Of Signal

Total=10

Category = bri|ds1|env|equipment|fxo|fxs|rtr|v35

Severity = alert|critical|info|major|minor

Clear Alarm

Once an alarm is identified then the process of clearing it can begin.

l

Silence Alarm, if necessary (Alarm Cut Off CLI command: aco)

l

Check Connection

l

Check Cable, replace if necessary

l

Check hardware and replace if necessary

l

Call Customer Service