Technical Specifications

Alarms

l

Support standard T1.403 alarms

Testing and Diagnostics

l

T1.403 payload loopbacks (ESF only)

l

T1.403 remote and local line loopbacks (ESF and SF)

l

DS0 loopbacks

l

T1.231 Performance History (15 minute intervals, 24 hour totals)

l

T1.203 Performance Report Messages (PRMs)

Power Consumption

l

Less than 3 W per card

Regulatory Approvals

USA

l

UL60950

l

FCC Part 15, Class A

l

FCC Part 68

l

NEBS Level 3 certified for type 2 and 4 equipment
GR-63-CORE, GR-1089-CORE

Canada

l

CSA C22.2 No. 60950-00

l

ICES-003, Class A

l

CS-03

Physical

l

Dimensions: 3.5 in. (H) x 0.75 in. (W) x 11.25 in. (D)
8.9 cm (H) x 1.9 cm (W) x 28.6 cm (D)

l

Weight: 5.1 oz. (0.14 kg)

For information on Compact T1 Environment required, see Installation Environment
on page 2-2.