Alarms, Testing and diagnostics, Power consumption – Black Box COMPACT T1 MT850A User Manual
Page 449: Regulatory approvals, Physical
![background image](/manuals/53231/449/background.png)
Compact T1 - Release 6.1
12-5
Quad T1 Card
Technical Specifications
Alarms
l
Support standard T1.403 alarms
Testing and Diagnostics
l
T1.403 payload loopbacks (ESF only)
l
T1.403 remote and local line loopbacks (ESF and SF)
l
DS0 loopbacks
l
T1.231 Performance History (15 minute intervals, 24 hour totals)
l
T1.203 Performance Report Messages (PRMs)
Power Consumption
l
Less than 3 W per card
Regulatory Approvals
USA
l
UL60950
l
FCC Part 15, Class A
l
FCC Part 68
l
NEBS Level 3 certified for type 2 and 4 equipment
GR-63-CORE, GR-1089-CORE
Canada
l
CSA C22.2 No. 60950-00
l
ICES-003, Class A
l
CS-03
Physical
l
Dimensions: 3.5 in. (H) x 0.75 in. (W) x 11.25 in. (D)
8.9 cm (H) x 1.9 cm (W) x 28.6 cm (D)
l
Weight: 5.1 oz. (0.14 kg)
For information on Compact T1 Environment required, see Installation Environment
on page 2-2.