Dip switch settings, Dip switch settings -9, T1 controller card – Black Box COMPACT T1 MT850A User Manual

Page 379

Advertising
background image

Compact T1 - Release 6.1

6-9

T1 Controller Card

Configuration

DIP Switch Settings

On the front of the TDM Controller card are DIP switches you can use to configure the
unit locally.

Switch

Function

Description

ACO

Alarm Cut
Off

0 = Alarm contacts enabled (close when alarm occurs).
Default.
1 = Alarm contacts disabled (open).

ST

Self Test

0 = Normal operation. Default.
1 = Perform Self Test.

OPT

Spare

RST

Reset

0 = User-configured operation. Default.
1 = Reset configuration to factory defaults, and reset CLI
password.

T1-1
T2-1

Line Coding

0 = B8ZS. Default.
1 = AMI

T1-2
T2-2

Line
Loopback

0 = Loopback off. Default.
1 = Loopback on

T1 3-4
T2 3-4

Framing

0 = ESF (Extended Superframe). Default.
1 = D4

T1 5 - 6
T2 5 - 6

Signaling

Switch 3

Switch 4

Switch 5

Switch 6

Setting

0

1

1

1

TR-08 A-Shelf with FDL, 16-bit Alarm frame

1

0

0

0

TR-08 A-Shelf with FDL, 13-bit Alarm frame

1

0

0

1

TR-08 A-Shelf with FDL disabled

1

0

1

0

TR-08 B-Shelf

0

0

0

0

Loop Start/Ground Start. Default.

0

0

0

1

E&M Immediate Start with ringback. (used for D3 PLAR
and DPT)

0

0

1

0

E&M Immediate Start with ringback and Calling Party
Disconnect (CPD)

Advertising