Alarms, Test alarm, Identify alarm – Black Box COMPACT T1 MT850A User Manual

Page 530

Advertising
background image

B-2

Compact T1 - Release 6.1

Diagnostices & Troubleshooting

Alarms

Alarms

Test Alarm

The Commpact T1 alarm functions can be manually tested using the following
command for setting critical, major and minor alarms. Turning alarms on or off will
produce alarm messages and log entries stating the alarm event was manually set/
cleared by the user.

Syntax:

set alarms {critical|major|minor} {off|on}

Identify Alarm

Alarm indicators

l

LEDs - When an Alarm is triggered, the LED (labeled CRD) will display a

red indicator light, which will stay on until the Alarm is cleared

. The

following is the LED information for the T1 Controller card. For LED
infomation for the specific service card see the chapter for that card.

LED

State

Description

MAJOR

Off

No major alarms present

Red

Major alarm present

MINOR

Off

No minor alarms present

Yellow

Minor alarms present

LOCAL

Off

Remote mode (DIP switches disabled)

Green

Local mode (DIP switches enabled)

ACO

Off

Normal mode. No alarms are being suppressed.

Yellow

Alarm cutoff active. One or more active alarms
suppressed.

T1-1 and
T1-2

Off

Off line

Green

Normal

Red

Loss of Signal (LOS) detected

Yellow

Bipolar Violation (BPV) detected

Flashing Green

Loopback active

Flashing Red

Loss of Frame (LOF) or Alarm Indication Signal
(AIS) detected

Flashing Yellow

Yellow alarm (Remote Alarm Indication) detected.