Wiring of the standard device, Stop – Lenze EVS9332xS User Manual

Page 141

Advertising
background image

Wiring of the standard device

Control terminals
Important notes

5

5.8
5.8.1

l

5.8−2

EDSVS9332S EN 6.0−07/2013

1

2

0

9300vec129

Fig. 5.8−1

Connection of cable shield to shield sheet

0 Shield sheet

1 Fasten shield sheet with M4 × 10 mm screw at the bottom of the control

card

2 Securely clamp cable shield with lugs

(

Stop!

ƒ

Connect or disconnect the terminal strips only if the controller
is disconnected from the mains!

ƒ

Wire the terminal strips before connecting them!

ƒ

Unused terminal strips must also be plugged on to protect the
contacts.

Cable type

Wire end ferrule

Maximum cable
cross−section

Tightening
torque

Stripping
length

Rigid

2.5 mm

2

(AWG 14)

0.5 ... 0.6 Nm

(4.4 ... 5.3 lb−in)

5 mm

Flexible

Without wire end
ferrule

2.5 mm

2

(AWG 14)

Flexible

Wire end ferrule
without plastic
sleeve

2.5 mm

2

(AWG 14)

Flexible

Wire end ferrule
with plastic sleeve

2.5 mm

2

(AWG 14)

How to connect the shield