Configuration, Code table – Lenze EVS9332xS User Manual

Page 260

Advertising
background image

Configuration

Code table

8

8.4

l

8.4−19

EDSVS9332S EN 6.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C0465

s

FB LIST

®

® Selection list 5 FB processing list

Includes the program for signal processing
(sequence in which the function blocks are
processed)

à

Depending on C0005. Change of C0005
loads assigned processing list

à

Valid for C0005 = 1000

l

After changing the signal flow the
processing list must be adapted.
Otherwise the device may work with
wrong signals!

l

The function blocks DIGIN, DIGOUT,
AIF−IN, CAN−IN, and MCTRL are always
processed and do not have to be entered
in the list.

1

200

2

0

3

50

4

0

5

0

6

55

7

0

8

0

9

10250

10

0

11

0

12

0

13

5650

14

0

15

0

16

5050

...

0

19

5700

...

0

22

10650

...

0

25

70

..

0

28

75

...

0

31

250

...

0

41

25000

42

20000

...

0

49

0

50

0

C0466 CPU T REMAIN

g

Remaining process time
For processing function blocks

C0469

s

KEY
STOPFUNCTIO
N

2

0
1
2

switched off
set controller inhibit
set quick stop

set function of the STOP key on the keypad

C0470

0

{1}

255 Freely configurable code for digital signals

l

Data words C0470 and C0471 are in
parallel and identical

0 FCODE 8BIT

DIGITAL

0

1 FCODE BIT 0−7

0

2 FCODE BIT8−15

0

3 FCODE

BIT16−23

0

4 FCODE

BIT24−31

0