Configuration

Code table

8

8.4

l

8.4−9

EDSVS9332S EN 6.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C0141 FCODE

(SETVAL)

0.0

−199.9

{0.1 %}

199.9 Main setpoint

C0142 START

OPTIONS

1

Start option

0

Start lock

l

Automatic start inhibited after
– Mains connection
– Reset of a message (t > 0.5 s)
– TRIP RESET

l

Start after HIGH−LOW−HIGH level change
at X5/28

1

Auto start

Automatic start if X5/28 = HIGH

C0150 STATUS WORD

g 0

{1}

65535 Status word when linked to automation

interfaces

l

Binary interpretation indicates the bit
states

C0151 FDO (DW)

g

Hexadecimal display of the free digital
output signals configured in C0116

l

Binary interpretation indicates the bit
states

C0155 STATUS WORD

2

g Bit00

Fail

Bit08

R/L

Status word 2
Extended decimal status word

l

Binary interpretation indicates the bit
states

Bit01

Mmax

Bit09

Bit02

Imax

Bit10

Bit03

IMP

Bit11

Bit04

RDY

Bit12

Bit05

RSP

Bit13

Bit06

Trip

Bit14

Bit07

Init

Bit15

C0156

s

® Selection list 2 Configuration of the free bits of the status

word

1 STAT.B0

2000 DCTRL−PAR*1−O

2 STAT.B2

5002 MCTRL−IMAX

3 STAT.B3

5003 MCTRL−MMAX

4 STAT.B4

5050 NSET−RFG I=O

5 STAT.B5

10650 CMP1−OUT

6 STAT.B14

505

DCTRL−CW/CCW

7 STAT.B15

500

DCTRL−RDY

C0157

g

Display of the freely definable bits of the
status word

1 (C0156/1)

... ...

7 (C0156/7)

C0161 ACT TRIP

g All fault messages

Trip error message
Current fault message (as in C0168/1)

C0167 RESET

FAILMEM

0

0
1

No reset
Reset

Reseterror message
C0167 = 1 deletes the history buffer

C0168

g All fault messages

List of faults occurred

1 FAIL NO. ACT

Currently active fault

2 FAIL NO. OLD1

Last fault

... ...

...

8 FAIL NO. OLD7

Last but six fault

Advertising