Configuration, Code table – Lenze EVS9332xS User Manual

Page 248

Advertising
background image

Configuration

Code table

8

8.4

l

8.4−7

EDSVS9332S EN 6.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C0094 PASSWORD

0

0

{1}

9999 Password

l

Parameter access protection for the
keypad. When the password is activated,
only codes of the user menu can be
accessed. For further possible selections
see C0096

C0095

s

ROTOR POS
ADJ

0

0
1

Inactive
Active

Rotor position adjustment of a synchronous
motor

l

C0058 displays the zero angle of the rotor

l

C0095 = 1 starts position adjustment

C0096

s

0
1
2
3

No access protection
Read protection
Write protection
Read/write protection

Extended password protection for bus
systems with activated password (C0094).

l

All codes in the user menu can be
accessed.

1 AIF PROTECT.

0

AIF access protection

2 CAN PROTECT.

0

CAN access protection

C0099 S/W VERSION

g x.xx

Software version

C0101

0.000

{0.001 s}

999.900 NSET

Additional acceleration for the main setpoint
(based on speed variation 0...n

max.

)

1 NSET−TIR

(ACCELERATIO
N)

0.000

2 NSET TIR

0.000

... ...

...

15 NSET−TIR

0.000

C0103

0.000

{0.001 s}

999.900 NSET

Additional deceleration times for the main
setpoint
(based on speed variation 0...n

max.

)

1 NSET−TIF

0.000

2 NSET−TIF

0.000

... ...

...

15 NSET−TIF

0.000

C0105 QSP TIF

0.000 0.000

{0.001 s}

999.900 QSP deceleration time

Deceleration time for quick stop (QSP)
(based on speed variation 0...n

max.)

C0108

100.0

0

−199.99

{0.01 %}

199.99 FCODE (AOUT gain)

1 FCODE (GAIN

AOUT)

2 FCODE (GAIN

AOUT)

C0109

−199.99

{0.01 %}

199.99 FCODE (offset AOUT)

1 FCODE (OFFSET

AOUT)

0.00

2 FCODE (OFFSET

AOUT)

0.00

C0114

0
1

HIGH active
LOW active

DIGINterminal polarity

1 DIGIN1 POL

0

X5/E1

2 DIGIN2 POL

0

X5/E2

3 DIGIN3 POL

0

X5/E3

4 DIGIN4 POL

1

X5/E4

5 DIGIN5 POL

0

X5/E5