Configuration, Code table – Lenze EVS9332xS User Manual

Page 254

Advertising
background image

Configuration

Code table

8

8.4

l

8.4−13

EDSVS9332S EN 6.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C0264 MPOT1

ON/OFF

0

0
1
2
3
4
5

No change
Deceleration with T

if

to 0%

Deceleration with T

if

to C0261

Skip with T

if

= 0 to 0%

Skip with T

if

= 0 to C0261

Acceleration with T

ir

to C0260

MPOT1
Executable functions if motor potentiometer
is deactivated via input MPOT1−INACTIVE.

C0265 MPOT1 INIT

0

0
1
2

Value during mains failure
Lower limit value from C0261
0 %

MPOT1
Initialisation
Value which is accepted during mains
switching and activated motor pot.

C0267

s

® Selection list 2 MPOT1

Configuration of digital input signals

1 UP

1000 FIXED0

2 DOWN

1000 FIXED0

C0268

s

MPOT1−INACT

1000 FIXED0

® Selection list 2 MPOT1

Configuraton of digital input signal

C0269

g

1 (C0267/1)

2 (C0267/2)

3 (C0268)

C0291 SSC OVERRIDE

0

0

{1 rpm}

16000 SSC cutout frequency

Cutout frequency for the transition from
sensorless control to controlled operation

C0292 SSC IM SET

0.00

0.00

{0.01 A}

500.00 SSC Im setpoint

Motor current setpoint.
For sensorless control, set 1.0 ... 1.1−fold rated
motor current.

C0293 SSC DYNAMIC

0.00

0.00

{0.01 %}

199.00 SSC dynamic constant

C0294 VP FRQ CTRL

®

0.0

{0.1}

99.9 Vp frequency controller

Proportional gain of frequency controller

à

Depending on C0086

C0295 TN FRQ CTRL

®

2

{1 ms}

20000 Tn frequency controller

Adjustment time frequency controller

à

Depending on C0086

C0296 DYNAMIC

CONST

100

0

{0.1}

32767 Dynamic constant

C0325 VP2 ADAPT

1.0

0.1

{0.1}

500.0 PCTRL Adpation Vp2

Process controller adaptation gain (V

p2

)

C0326 VP3 ADAPT

1.0

0.1

{0.1}

500.0 PCTRL adaptation Vp3

Process controller adaptation gain (V

p3

)

C0327 SET2 ADAPT

100.0

0

0.00

{0.01 %}

100.00 PCTRL adaptation nset2

Set speed threshold of the process controller
adaptation (condition: C0327 > C0328)

C0328 SET1 ADAPT

0.00

0.00

{0.01 %}

100.00 PCTRL adaptation nset1

Set speed threshold of the process controller
adaptation (condition: C0328 < C0327)

C0329 ADAPT ON/OFF

0

0
1
2
3

No process controller adaptation
External via input
Adaptation via setpoint
Adaptation via control difference

PCTRL Adaptation on/off
Activate process controller adaptation

C0332 PCTRL TIR

0.000 0.000

{0.001 s}

999.900 PCTRL

Acceleration time T

ir

(relating to setpoint change 0...100 %)

C0333 PCTRL TIF

0.000 0.000

{0.001 s}

999.900 PCTRL

Deceleration time T

if

(based on setpoint change 0...100 %)